verify_heater: Change default hysteresis to 10 degrees
A default of 4 degrees and 10 seconds may be too aggressive - change the default to 10 degrees and 15 seconds. Signed-off-by: Kevin O'Connor <kevin@koconnor.net>
This commit is contained in:
@@ -11,8 +11,8 @@ class HeaterCheck:
|
||||
self.printer = config.get_printer()
|
||||
self.heater_name = config.get_name().split()[1]
|
||||
self.heater = None
|
||||
self.hysteresis = config.getfloat('hysteresis', 4., above=0.)
|
||||
self.check_time = config.getfloat('check_time', 10., minval=1.)
|
||||
self.hysteresis = config.getfloat('hysteresis', 10., above=0.)
|
||||
self.check_time = config.getfloat('check_time', 15., minval=1.)
|
||||
self.heating_gain = config.getfloat('heating_gain', 2., above=0.)
|
||||
default_gain_time = 20.
|
||||