34 lines
1.3 KiB
Markdown
34 lines
1.3 KiB
Markdown
---
|
|
layout: default
|
|
title: Deprecated Values
|
|
parent: Klipper Warnings
|
|
grand_parent: FAQ
|
|
nav_order: 10
|
|
has_children: false
|
|
permalink: /faq/klipper_warnings/deprecated_value
|
|
has_toc: false
|
|
---
|
|
|
|
# Deprecated Values
|
|
|
|
###### NTC 100K beta 3950
|
|
## Removal of `NTC 100K beta 3950` sensor type.
|
|
|
|
The "NTC 100K beta 3950" temperature sensor is _deprecated_ and will be removed in the near future.
|
|
|
|
In order to solve the problem search in your config for `sensor_type: NTC 100K beta 3950` and replace it with `sensor_type: Generic 3950`.
|
|
|
|
Most users will find the "Generic 3950" temperature sensor more accurate. Anyway you can continue to use the older (typically less accurate) definition. Therefor define a custom thermistor with `temperature1: 25`, `resistance1: 100000`, and `beta: 3950`.
|
|
|
|
[Source](https://www.klipper3d.org/Config_Changes.html){:target="_blank"} Klipper Configuration Changes
|
|
{: .info}
|
|
|
|
###### rpi_temperature
|
|
## Removal of `rpi_temperature` sensor alias.
|
|
|
|
Replace `sensor_type: rpi_temperature` by `sensor_type: temperature_host` everywhere in your config.
|
|
|
|
The above description was provided by our community member [FHeilmann](https://github.com/FHeilmann){:target="_blank"} and we have his permission to publish it here. Thanks a lot!
|
|
[Source](https://gist.github.com/FHeilmann/a8097b3e908e85de7255bbe6246ddfd5){:target="_blank"}.
|
|
{: .info}
|