# Zcalibrate
This panel supports various modes of operation to assist in the calibration of the Z axis of the machine.
It's strongly suggested to read Klipper documentation about [Bed level](https://www.klipper3d.org/Bed_Level.html)
![Screenshot](../img/panels/zcalibrate.png)
## Buttons
* "Start" will initiate the only method available, or ask the user if multiple methods are available.
!!! note
KlipperScreen will automatically Home(`G28`) if needed
* The raise(+) and lower(-) buttons send `TESTZ Z=distance` where distance is selected in the bottom row.
* Accept will send `ACCEPT`
* Abort will send `ABORT`
## Calibration methods
### Probe (`PROBE_CALIBRATE`)
Available when a probe is defined. (BL-Touch is a probe)
KlipperScreen will try to position the probe in the correct place before sendind a `PROBE_CALIBRATE`
??? info "Search order to select location"
1. `calibrate_x_position` and `calibrate_y_position` in [KlipperScreen.conf](https://klipperscreen.readthedocs.io/en/latest/Configuration/#printer-options)
Both need to be configured, probe offsets are not applied. This is considered an override
2. Probe at the [zero reference position of the mesh](https://www.klipper3d.org/Bed_Mesh.html#configuring-the-zero-reference-position)
3. If `[safe_z_home]` is defined, those values are used. Unless `Z_ENDSTOP_CALIBRATE` is available.
In other words, only use `[safe_z_home]` if `z_virtual_endstop` is used
4. If the kinematics are `delta` probe is placed at 0, 0
5. Probe at the center of the `bed_mesh`
6. Probe at the center of the axes (`position_max` / 2)
Klipper documentation: [Calibrating probe Z offset](https://www.klipper3d.org/Probe_Calibrate.html#calibrating-probe-z-offset)
### Endstop (`Z_ENDSTOP_CALIBRATE`)
Available when a physical endstop is defined for `[stepper_z]`
Klipper documentation: [Calibrating a Z endstop](https://www.klipper3d.org/Manual_Level.html#calibrating-a-z-endstop)
### Bed mesh (`BED_MESH_CALIBRATE`)
Available when a probe is not defined and `[bed_mesh]` is defined
this mode lets you create a mesh leveling bed using the paper test in various points.
!!! warning
DO NOT adjust the bed screws while using this mode.
Adjust the screws using the [bed screws](Screws.md) panel before running this tool.
### Delta Automatic/Manual (`DELTA_CALIBRATE`)
Available when the kinematics are defined as delta.
Klipper documentation: [Delta calibration](https://www.klipper3d.org/Delta_Calibrate.html)
### Axis Twist Compensation (`AXIS_TWIST_COMPENSATION_CALIBRATE`)
Available when `[axis_twist_compensation]` is defined in the Klipper configuration.
Klipper documentation: [Axis Twist Compensation](https://www.klipper3d.org/Axis_Twist_Compensation.html)